DIGISTANT® 4463 High-precision multifunction calibrator for voltage, current, thermocouples, RTDs, resistance and frequency

Our calibration source is the smart, convenient and traceable answer to your calibration requirements. The DIGISTANT® 4463 enables fully automated test and simulation sequences for your measuring equipment or transducers.

Product Inquiry

    Product comparison

      • Features

        • DC voltage ±100 nV … ±100 V (accuracy from 0.002 %)
        • DC current ±100 nA … ±50 mA (accuracy 0.005 % ±1 µA)
        • 12 thermocouple types (accuracy from 0.1 K)
        • 32 automatic ramp functions per measured variable, each with 100 values
        • LabView driver for software integration
      • Product data

        Model 4463
        DC voltage simulation

        ±300 mV
        ±3 V
        ±30 V
        ±100 V

        Measurement accuracy voltage simulation ±0.002 %
        DC voltage measurement No
        DC current simulation

        ±25 mA
        ±50 mA

        Measurement accuracy current simulation ±0.005 % ±1 µA
        DC current measurement No
        Thermocouples simulation and measurement Yes
        RTD simulation and measurement Yes
        Interfaces RS-232 (D-sub 9)
        USB slave port (type B)
        Ethernet Western socket (RJ45)
        Supply voltage

        230 V ±10 % / 47 ... 63 Hz
        115 V ±10 % / 47 ... 63 Hz

        Specific characteristics

        • DC voltage ±100 nV … ±100 V (accuracy from 0.002 %)
        • DC current ±100 nA … ±50 mA (accuracy 0.005 % ±1 µA)
        • 12 thermocouple types (accuracy from 0.1 K)
        • 32 automatic ramp functions per measured variable, each with 100 values
        • LabView driver for software integration
      • Description

        The DIGISTANT® model 4463 is a high-precision calibration source with impressive versatility and accuracy. Every device is supplied with a DAkkS certificate. Compared to other calibrators, it offers a better error limit of 0.002 % across the entire voltage range.

        To achieve consistently high quality levels and conform to standards and regulations, measuring instruments of all kinds require regular calibration. The DIGISTANT® model 4463 provides many of the functions needed for this purpose. Inaccuracies caused by the measuring leads can be compensated via sense lines using 4-wire technology.

        All relevant information about the parameter settings and the accuracy being achieved is clearly laid out on the high-resolution color display. The dynamic menu system is navigated intuitively. Range selection is automatic or manual. Values can be entered precisely using the numeric or cursor keypad.

        The device can be controlled via its Ethernet, USB or RS-232 port. LabView drivers for software integration are available free of charge. SCPI commands are listed in the user manual. 32 ramp functions per range with 100 value/time sequences can be automatically saved and started.

        For thermocouples, scales including ITS-90 and IPTS-68, reference junction type constant or external, can be selected. An optionally available external Pt100 reference junction with calibration data taken into account in the device minimizes thermal EMFs and results in even smaller uncertainties in the measurement chain.

      • Data Sheet & Downloads

        Data sheet
        Further info
        Operation manual
        Software
      • Accessories

        pdf Mounting kit für 19"/5HE control cabinet installation
        pdf External reference junction for thermocouples Model 4485-V001
      • Videos

        Please accept marketing-cookies to watch this video.

        High-Precision Calibration Source DIGISTANT® 4463


        Youtube channel Burster Youtube Channel



      burster in Germany

      burster praezisionsmesstechnik gmbh & co kg
      +49 7224645-0
      infoburster.com
      www.burster.com

      Company-Information Company-Information

      Germany

      burster praezisionsmesstechnik gmbh & co kg

      Talstr. 1-5
      76593 Gernsbach
      Germany

      Fon: +49 7224645-0
      Fax: +49 7224645-88
      infoburster.com
      www.burster.com

      ×
      © 2024 // burster präzisionsmesstechnik gmbh & co kg
      nach oben