Resistance simulation |
Resistance range: 1 mΩ … 300 mΩ Standard values: 1 mΩ, 3 mΩ, 5 mΩ, 10 mΩ, 15 mΩ, 30 mΩ, 50 mΩ, 100 mΩ, 150 mΩ, 300 mΩ Repeat accuracy from ±0.2 % F.S.* Max. simulation test current: ±0.8 A Special values: on request
* In the case of interference radiation with frequencies in the range of 500 ... 550 MHz and simultaneous amplitude modulation at 1 kHz deviations of up to ±0.8 % can occur if the measurement frequency of the AC measurement is also 1 KHz.
|