Factory Calibration Certificate Factory Calibration

You can use the burster factory calibration certificate to comply with requirements for the monitoring and measuring equipment used in the automotive and medical sectors and aerospace industries.

The burster factory calibration certificate provides you with the necessary information on measurement uncertainty, procedures and traceability both for individual sensors and complete measurement systems. burster calibration can also be customized to individual requirements.

Product Inquiry

    Product comparison

      • Product data

        Model WKS
        Load cell or measurment chain

        Measuring range: 0 N ... 10 kN 
        Uncertainty: 0.1 % rdg.

        Measuring range: > 10 kN ... 200 kN 
        Uncertainty: 0.1 % F.S.

        Measuring range: > 200 kN ... 2 MN with external partners

        Torque sensor or measurement chain

        Measuring range: 0.05 ... 250 Nm 
        Uncertainty: 0.12 % rdg.

        Measuring range: 250 Nm ... 5 kNm with external partners

        Pressure sensors or measurement chain (absolute pressure)

        Measuring range: 0.1 ... 35 bar 
        Uncertainty: 0.04 % rdg. (but not less than 60 μbar)

        Measuring range: 35 ... 1400 bar with external partners

        Pressure sensor or measurement chain (excess pressure)

        Measuring range: 0 ... 1400 bar 
        Uncertainty: 0.04 % rdg. (but not less than 60 μbar)

        Measuring range: 1400 ... 5000 bar with external partners

        Displacement sensor or measurement chain

        Measuring range: 0 ... 100 mm 
        Uncertainty: U(L) = (0.5+L/150+0.04*L) μm

        Measuring range: 100 ... 300 mm with external partners

        DC voltage

        Measuring range // smallest readable uncertainty

        • 10 μV ... 200 V // (5 + 0.2 V/U) * 10-6  
        • 1 V // 2 * 10-6
        • 1.02 V // 2 * 10-6
        • 10 V // 2 * 10-6
        DC current

        Measuring range// smallest readable uncertainty

        • 1 μA ... 100 mA // 10 * 10-6
        • > 100 mA bis 1 A // 20 * 10-6
        • > 1 A bis 10 A // 50 * 10-6
        • > 10 A bis 500 A // 10 * 10-5
        • Above 30 A, only calibration of current sources, not of ammeteres

        DC resistance

        Measuring range // smallest readable uncertainty

        • 0.1 mΩ ... < 1 mΩ // 50 * 10-6
        • 1 mΩ ... < 10 Ω // 10 * 10-6
        • 10 Ω ... 100 kΩ // 5 * 10-6
        • > 100 kΩ ... 1 MΩ // 10 * 10-5
      • Description

        The burster factory calibration certificate includes the following services:

        1. Assessing whether your measuring equipment is suitable for calibration.
        2. Performing a calibration.
        3. Documentation in the form of a factory calibration certificate.
        4. Identifying calibrated items with a calibration label.

        If we find during our calibration-suitability check that an adjustment is needed, we perform this adjustment prior to calibration in close consultation with you.

      • Data Sheet & Downloads

        Further info
      • FAQ

        1. Which products can burster calibrate?
          burster can calibrate and adjust all burster products. Calibration and adjustment of all sensors is performed either in burster laboratory or at a partner facility.
          Additionally, burster can calibrate sensors and equipment from other manufacturers after coordinating technical details.
        2. How long does a calibration take?
          Typically, a standard calibration takes 1 to 2 weeks after the test items are received and pending technical questions are resolved.
        3. What does a calibration involve?
          Every product is subject to an assessment of suitability for calibration prior to its calibration. If we find out that adjustments are needed, we contact you and after you go-ahead, we make the necessary adjustments and then repeat the calibration. All calibrations are performed in accordance with internationally standardized methods. 
        4. What quality standards are met by a factory calibration (WKS)?
          With a burster factory calibration you can be confident of compliance with all the quality systems used in the automotive, aerospace, pharmaceutical, medical and defence industries, such as ISO 9001, ISO 16494, ISO 13485, ISO 10012.
        5. What is "suitability for calibration"?
          When you send burster a product for calibration, we check prior to the actual calibration, that your unit is working properly electrically.
        6. What is the difference between calibration and adjustment?
          Calibration establishes the measurement range and accuracy of your instrument or test equipment. If it is found during calibration, that the measurement ranges or accuracy can no longer meet the product specifications guaranteed by burster, then it may be possible to adjust a unit so that it complies again with the promised specification.

      burster in Germany

      burster praezisionsmesstechnik gmbh & co kg
      +49 7224645-0
      infoburster.com
      www.burster.com

      Company-Information Company-Information

      Germany

      burster praezisionsmesstechnik gmbh & co kg

      Talstr. 1-5
      76593 Gernsbach
      Germany

      Fon: +49 7224645-0
      Fax: +49 7224645-88
      infoburster.com
      www.burster.com

      Trade fairs

      Wire
      15.04. - 19.04.24 - Düsseldorf, 40474, Germany  

      The Battery Show
      18.06. - 20.06.24 - Stuttgart, 70269, Deutschland  

      ×
      © 2024 // burster präzisionsmesstechnik gmbh & co kg
      nach oben