on batteries for determining suitability
The battery quality of round cells must be determined on sample parts with the aid of the capacity, voltage and internal resistance parameters. The primary cell is fully charged for determining the capacity. The discharging of the cell takes place using a selectable constant current as far as the discharge limit voltage by the battery tester. The frequency-dependent internal resistance of a cell contains real and imaginary components, and is displayed as a Nyquist plot via the spectral impedance measurement within the frequency range of 0.1 Hz to 1 kHz. Electrochemical characteristics can be assigned from this and checking for possible fluctuations during manufacturing can take place. Important model parameters such as series resistance (Rs, electrolyte statement), parallel resistance (Rp, electrode characteristic) and capacity (Cp, double layer capacity) can be calculated.
Visualisation, calculation, archiving via PC software
Measurement of cell voltage, capacity, temperature, spectral impedance measurement, calculation of Rs, Rp and Cp.