TRANS CAL 7281 Mobile high-precision calibrator and testing device for mechanical and electrical measurements

Device test, strain gauge simulator, sensor test, reference measurement chain

Product Inquiry

    Product comparison

      • Features

        • Supported sensors: Strain gauge/normalized signal ± 5V, ± 10 V, potentiometric sensors
        • Device test: Strain gauge simulator up to ± 50 mV/V
        • Easy adjustment through burster TEDS
        • Excellent linearity with non-linearity < ± 0.001 %
        • Storage of up to 16 measurement programs
        • Data logger for up to 30.000 measurements
        • Factory calibration certificate and / or German accredited DKD / DakkS calibration certificate optionally available for the instrument / entire measurement chain
      • Product data

        Model 7281
        Measurement accuracy < ± 0.001 % F.S.
        Sample rate

        0.1 … 1200/s (DC)
        0.1 … 2/s (AC)

        Type of sensor

        • Strain gauge
        • Potentiometer
        • Transmitter
        • Sensors and devices with voltage output
        Interfaces USB 2.0
        Sensor excitation

        Strain gauge:

        • DC: 2.5 V / 5 V (for 120 Ω only 2.5 V)
        • AC: 2.5 Veff / 5 Veff (from 350 Ω)

        Potentiometer:

        • 5 VDC

        Transmitter:

        • 12 VDC ± 5 %
        Protection class IP40
        Supply voltage 10 ... 28 VDC
        Reference measurement device Yes
        Sensor test Yes
        Device test Yes
        Strain gauge simulator Yes
        Data logger Yes
        Electronic sensor data sheet Yes
        Connection type 4 / 6 wire connection
        Measurement programs 16
        Specific characteristics

        • Device test: Strain gauge simulator up to ± 50 mV/V
        • Easy adjustment through burster TEDS
        • Storage of up to 16 measurement programs
        • Data logger for up to 30.000 measurements
        • Factory calibration certificate and / or German accredited DKD / DakkS calibration certificate optionally available for the instrument / entire measurement chain
      • Description

        The multipurpose digital indicator TRANS CAL 7281 can be used wherever there is a need to perform high-precision, in-situ calibrations of sensing components used in equipment such as presses, torque tools or pressure-regulating systems. An optional factory calibration certificate or German-accredited DKD/DAkkS calibration certificate can be provided when the measurement device needs to be used as a reference. This provides a quick and cost-effective way of assessing a system with traceable documentation of measurement results.

        If a reference measurement cannot be made because the sensor location is difficult to access, it is still possible to test the zero point, the input, output and isolation resistance as well as the calibrating offset of the fitted sensor. It is also possible to check the indicating device by measuring the excitation voltage and simulating the characteristic values (mV/V or V) of the sensor used.

        The instrument is used in metrology institutes, calibration laboratories and in industry in the fields of quality assurance, facility commissioning and system monitoring.

        Areas of use:

        • Checking hydraulic presses
        • Reference measurements in assembly lines
        • Test of robotic pressing forces
        • Calibrating test equipment
        • Calibrating of high-precision measuring devices

        The TRANS CAL 7281 can be fitted with standard or rechargeable batteries for portable use or can run from an external power supply. Combined with a reference sensor the testing device provides a high-precision reference measurement chain e.g. for force measurements, but is also ideal for service engineers as a tool for locating faults in device or sensors.

        The choice of sensors includes strain gauge, normalizedsignal ± 5 V / ± 10 V and potentiometric sensors. The LCD graphics display shows the live measurement value and the corresponding bar indicator. It also supports display functions such as data-logger, tared value in % and upper/lower limit for the comparator with simultaneous indicator (< = >) of the evaluation result.

        For routine testing and also fault-locating tasks, the tester makes it really simple to measure isolation resistances and input/output resistances. The equipment test function is a quick and easy way to verify that the display device complies with the characteristic value, offering strain-gage simulation of up to ± 50 mV/V or output of a normalized signal of up to 10 V. German-accredited DKD/DAkkS calibration certificates or factory calibration certificates are optionally available. The DigiCal configuration and data-acquisition software provides useful display and reporting functions.

      • Data Sheet & Downloads

        Data sheet
        Operation manual
        Software
        Further info
      • Accessories

        pdf Aluminium case for TRANS CAL 7281 and accessories
      • Videos

        Please accept marketing-cookies to watch this video.

        Motek exhibition video burster 2015

        Please accept marketing-cookies to watch this video.

        burster Calibration to go Control 2015


        Youtube channel Burster Youtube Channel

      • Application Examples

        Calibrating a hydraulic press

        using a reference measurement

        Flight testing

        of a paraglider

      Related products



      burster in Germany

      burster praezisionsmesstechnik gmbh & co kg
      +49 7224645-0
      infoburster.com
      www.burster.com

      Company-Information Company-Information

      Germany

      burster praezisionsmesstechnik gmbh & co kg

      Talstr. 1-5
      76593 Gernsbach
      Germany

      Fon: +49 7224645-0
      Fax: +49 7224645-88
      infoburster.com
      www.burster.com

      Trade fairs

      SPS - Smart Production Solutions
      12.11. - 14.11.24 - Nürnberg, 90471, Germany  

      ×
      © 2024 // burster präzisionsmesstechnik gmbh & co kg
      nach oben